OpenViolations
/

515 West 48 Street

ManhattanBIN 1027016
1 open Class C$3,000.00 recorded as dueHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
1
Immediately hazardous
Open Class B
3
Hazardous
Open Class A
6
Non-hazardous
Fines due
$3,000.00
Balance on OATH/ECB summonses
Permits on file
2
DOB permit records
Last activity
Jul 16, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

B
Health score · Jul 29, 2026
Scored from all 168 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 1
Open Class B violations
Hazardous
This building 3
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $3,000
Bedbug filings with infestations
Annual LL69 filings on record
This building 1
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Every record from every agency, interleaved. 168 records on file.

Download this timeline (CSV) →
Jul 16, 2026
Jul 16, 2026
Jul 16, 2026
Jul 16, 2026
Dec 15, 2025
Dec 20, 2024
Sep 30, 2024
May 6, 2024
May 2, 2024
May 2, 2024
May 2, 2024
May 2, 2024
May 2, 2024
Apr 29, 2024
Apr 25, 2024
Apr 19, 2024
Feb 29, 2024
Dec 12, 2023
Jun 21, 2023
May 3, 2023
Mar 16, 2023
Mar 1, 2023
Jan 27, 2023
Aug 3, 2022
Aug 3, 2022
Mar 22, 2022
Apr 7, 2021
Mar 25, 2021
Feb 3, 2021
Jan 30, 2021

OATH / ECB summonses & fines

$3,000.00 is recorded as due across the 13 summonses below, out of $26,782.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 515 West 48 Street
705979Jul 16, 2026OSP: OBSERVED UNPROTECTED OPENING FOR PIPES A/C LINES INTO U NITS AND Sep 24, 2026PENDING$1,250.00
1561032Jul 16, 2026ATOI AT ROOF: OBSERVED SEVEN (7) A/C CONDENSER UNITS INSTALLED ON DUNNSep 24, 2026PENDING$1,250.00
1561113Jul 16, 2026ATOI AT FAIL TO MAINTAIN BASEMENT OBSERVED OPEN ENERGIZED ELECTRICAL ESep 24, 2026PENDING$500.00
1657194Apr 29, 2024WORK WITHOUT A PERMIT. NOTED: AT EXPOSURE #1 OBSERVED MASONRY CLADDINGJul 11, 2024STIPULATION/IN-VIO
1609844Feb 3, 2021MISSING SHUT OFF VALVE AND ANTI SIPHON VALVE AT OIL TANK. MISSING TANKOct 14, 2021DEFAULT
1207566Jun 7, 2016FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: FAILURE TO PROVIDE Sep 15, 2016IN VIOLATION
1207575Jun 7, 2016SEC: BC907.2.8. FAILURE TO PROVIDE FIRE ALARM SYSTEM IN TRANSIENTLY OCSep 15, 2016IN VIOLATION
1207565Jun 7, 2016PERMANENT DWELLING USED/CONVERTED TO OTHER THAN PERMANENT RESIDENTIAL Sep 15, 2016IN VIOLATION
770613Jun 7, 2016FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER: LACK OF A SYSTEM OFSep 15, 2016IN VIOLATION
1121255Apr 4, 2016PERMANENT DWELLING USED/CONVERTED FOR OTHER THAN PERMANENT-RESIDENTIALMay 19, 2016IN VIOLATION
1121278Apr 4, 2016FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER: FAILURE TO PROVIDE May 26, 2016IN VIOLATION
1121280Apr 4, 2016FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER: LACK OF A SYSTEM OFMay 26, 2016IN VIOLATION
1121283Apr 4, 2016SEC. 907.2.8 FAILURE TO PROVIDE FIRE ALARM SYSTEM IN TRANSIENTLY OCCUPMay 26, 2016IN VIOLATION