| 1662853 | Dec 24, 2025 | NEGATIVE AIR PRESSURE HAS BEEN OBSERVED IN THE BATHROOMS AND KITCHEN E | Dec 10, 2026 | PENDING | $1,250.00 |
| 1468928 | Dec 24, 2025 | OBSERVED THE FOLLOWING MECHANICAL VENTILATION FANS INSTALLED ON THE RO | Nov 10, 2026 | PENDING | $1,250.00 |
| 1580489 | Jul 20, 2021 | NO SST 40 HR CERTIFICATES.AT TIME OF INSPECTION OF ACTIVE 17 STORY ALT | Sep 30, 2021 | DEFAULT | $12,500.00 |
| 1780226 | Jul 20, 2021 | NO SST 40 HR CERTIFICATES.AT TIME OF INSPECTOIN OF ACTIVE 17 STORY ALT | Oct 27, 2022 | IN VIOLATION | — |
| 1780225 | Jul 20, 2021 | BC3301.12.2 PRE SHIFT SAFTEY CONTENT. AT TIME OF INSPECTION OF ACTIVE | Jan 27, 2022 | IN VIOLATION | — |
| 342876 | Sep 15, 2020 | PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICATIONS. AT THE TIME O | Jan 14, 2021 | IN VIOLATION | — |
| 343092 | Sep 15, 2020 | FAILURE TO MAINTAIN ADEQUATE HOUSEKEEPING. AT THE TIME OF MY INSPECTIO | Jan 14, 2021 | IN VIOLATION | — |
| 1547252 | Sep 15, 2020 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS &/OR APPROVED | Dec 3, 2020 | IN VIOLATION | — |
| 1498345 | Jun 18, 2020 | PEDESTRIAN PROTECTIONDOES NOT MEET CODE SPECIFICATIOSN (VERTICIAL MEME | Aug 27, 2020 | IN VIOLATION | — |
| 1525696 | Apr 4, 2019 | 2X10 INSIDE CAR PHONE NOT WORKING | May 30, 2019 | Resolved | — |
| 954250 | Jul 24, 2012 | EXPIRED PERMIT: NOTED: NOTIFICATION OF STAGING & OUTRIGGER BEAM USE BY | Sep 13, 2012 | DEFAULT | — |
| 953543 | Jul 27, 2011 | FAILURE TO PROVIDE APPROVED ACCEPTED SITE SAFETY PLANS AT JOB SITE AT | Sep 15, 2011 | IN VIOLATION | — |
| 953548 | Jul 27, 2011 | BC3309.10 FAILURE TO PROTECT ADJOINING ROOF SKYLIGHT AND ROOF OUTLET A | Sep 15, 2011 | IN VIOLATION | — |
| 292878 | Jul 22, 2008 | SEC. BC 3314.6.3. LIFELINES, TIEBACKS & SUSPENSION ROPES SHALL EACH BE | Dec 18, 2008 | IN VIOLATION | — |
| 61485 | Jul 22, 2008 | SEC. BC 3314.10.1 & 27-1045. SUSPENDED SCAFFOLDS SHALL BE ERECTED & OP | Dec 18, 2008 | STIPULATION/IN-VIO | — |
| 140986 | May 24, 1995 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Sep 14, 1995 | IN VIOLATION | — |
| 140978 | May 19, 1995 | FAILURE TO COMLPY WITH THE COMMISSIONR'S ORDER TO FILE A CERTIFICATE | Sep 14, 1995 | IN VIOLATION | — |
| 136293 | Jan 27, 1995 | FAILURE TO COMPLY EITH THE COMMISIONER'S ORDER TO FILE A CERTIFICATE | Apr 20, 1995 | IN VIOLATION | — |
| 138101 | Oct 4, 1994 | FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER TO FILE A CERTIFICATE | Mar 23, 1995 | IN VIOLATION | — |
| 47139 | Jun 1, 1994 | FAILURE TO MAINTAIN-INTERIOR.THE RELINED BATHROOM MECHANICAL FIXATION | Sep 22, 1994 | IN VIOLATION | — |
| 153740 | May 6, 1994 | FAILURE TO MAINTAIN: INTERIOR NOTED: THE REQUIRED MECHANICAL BATHROOM | Sep 22, 1994 | IN VIOLATION | — |
| 59931 | Sep 5, 1991 | FAILURE TO MAINTAIN:AN AWNING MADE OF CANVAS&ALLUMINUN FRAMING IS HAN | Oct 17, 1991 | IN VIOLATION | — |
| 80899 | Jul 10, 1991 | 47B,35P | Nov 7, 1991 | STIPULATION/IN-VIO | — |
| 80898 | Jul 10, 1991 | 21X,35P,74M,74M,58O,59O 74)PROVIDE PIT LADDER 74A)PROVIDE CAUSTRIREDFT | Nov 7, 1991 | STIPULATION/IN-VIO | — |
| 42915 | May 1, 1991 | POSTING OF PERMITS:AT TIME OF INSPECTION, NO PERMIT FOR SIDEWALK SHED | Jul 25, 1991 | IN VIOLATION | — |