| 753555 | Dec 20, 2017 | FAILURE TO SAFEGUARD ALL PERSONS & PROPERTY AFFETED BY CONSTRUCTION OP | Feb 8, 2018 | IN VIOLATION | — |
| 1255032 | Mar 20, 2017 | FAILURE TO SAFEGUARD-AT TIME OF INSPECTION OF A 11 STRY BUILDING UNDER | May 4, 2017 | IN VIOLATION | — |
| 1141194 | Mar 20, 2017 | NO TOE BOARDS-AT TIME OF INSPECTION OF A 11 STRY BUILDING UNDER CONSTR | May 5, 2017 | IN VIOLATION | — |
| 1117340 | Jan 19, 2017 | SAFETY MEASURES AND STANDARD.AT TIME OF INSPECTION-DOB INCIDENT CURTAI | Mar 9, 2017 | IN VIOLATION | — |
| 1176443 | Oct 29, 2016 | SEC. 3301.2 OVERHEAD PROTECTION FAILURE TO PROVIDE. AT TIME OF INSPECT | Dec 15, 2016 | IN VIOLATION | — |
| 1187207 | Oct 29, 2016 | HOUSEKEEPING. FAILURE TO MAINTAIN HOUSEKEEPING AS PER SECTION REQUIREM | Dec 15, 2016 | IN VIOLATION | — |
| 647884 | Jul 9, 2015 | FAILURE TO PROVIDE APPROVED/ACCEPTED PLANS A THE JOBSITE. AT TIME OF | Aug 27, 2015 | IN VIOLATION | — |
| 1113724 | Jul 9, 2015 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTON DOCUMENT.THE RESPONDENT | Aug 27, 2015 | IN VIOLATION | — |
| 647889 | Jul 9, 2015 | FAILURE TO MONITOR ADJOINING STRUCTURES FOR MOVEMENT IN ALL DIRECTION | Aug 27, 2015 | IN VIOLATION | — |
| 375220 | Apr 6, 2015 | FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER:LACK OF SYSTEM OF | May 21, 2015 | IN VIOLATION | — |
| 1068719 | Apr 6, 2015 | WORK W/O A PERMIT. OBSERVE IN CELLAR INSTALLED NEW RPZ ON WATER SERVIC | May 21, 2015 | IN VIOLATION | — |
| 1019231 | Feb 9, 2015 | WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENT OR AMENDMENTS: | Mar 26, 2015 | STIPULATION/IN-VIO | — |
| 388741 | Jan 20, 2015 | FAILURE TO HAVE SITE SAFETY MANAGER PRESENT DURING WORK UNDER PERMIT # | Mar 12, 2015 | ADMIT/IN-VIO | — |
| 654793 | Nov 13, 2013 | 97B07- UNSAFE OR IMPROPER USE OF (HOISTING EQUIPMENT). DURING ALT WORK | Feb 6, 2014 | IN VIOLATION | — |
| 919978 | Sep 24, 2013 | 97**05-FAILURE TO MAINTAIN ELEVATOR DEVICE RESPONDENT FAILED TO ALLOW | Feb 13, 2014 | ADMIT/IN-VIO | — |
| 705333 | Apr 19, 2013 | B251:97##05.FAIL TO MAINTAIN ELEVATOR DEVICE.RESPONDENT FAILED TO ALLO | Aug 8, 2013 | STIPULATION/IN-VIO | — |
| 705089 | Aug 18, 2008 | 56Y13.52H11.52BB12.97A11.97T07.61V11.32H10.100BB05.98M05.37I10.12Q03.7 | Oct 9, 2008 | STIPULATION/IN-VIO | — |
| 622420 | Feb 20, 2008 | FAILURE TO COMPLY WITH AN ORDER OF THE COMMISSIONERS TO CORRECT THE CO | May 23, 2008 | IN VIOLATION | — |
| 621886 | Oct 10, 2007 | OCCUPANCY CONTRARY TO THAT ALLOWED BY THE C OF O #14822. C OF O INDICA | Nov 29, 2007 | IN VIOLATION | — |
| 751636 | Oct 10, 2007 | WORK W/O PERMIT WORK NOTED:6TH FL ERECTED PARTITIONS & INSTALLED WATER | Nov 29, 2007 | IN VIOLATION | — |
| 703860 | Oct 3, 1997 | 46T75T 46-RESHACKLE HOIST CABLE TAG 75-PERFORM 5 YR TEST & TAG. | Feb 26, 1998 | IN VIOLATION | — |
| 607975 | Mar 24, 1997 | OCCUPANCY CONTRARY TO THAT ALLWED BY THE CERTIFICATE OF OCCUPANCY #148 | Aug 28, 1997 | IN VIOLATION | — |
| 511394 | Mar 24, 1997 | WORK WITH A PERMIT WORK NOTED: SHEETROCK PARTITIONS CONSTRUCTED ON 3RD | Aug 28, 1997 | IN VIOLATION | — |
| 135252 | Mar 30, 1995 | 75T, 46T, 49T, 74#, 28L, 15I. 74--PROVIDE PROPER CLEAREANCE BETWEEN | Oct 5, 1995 | IN VIOLATION | — |
| 123814 | Feb 10, 1994 | 17I, 15L, 18L. (15) + (18) FIRST FLOOR | Feb 2, 1995 | IN VIOLATION | — |