| 982117 | Jul 22, 2022 | AT TIME OF INSPECTION I REQUESTED TO SEE THE FOLLOWING: 1) PRINTED DES | Nov 3, 2022 | IN VIOLATION | — |
| 1639285 | Jul 22, 2022 | FAILURE TO HAVE RIGGER OR DESIGNATED RIGGING FORMAN ON SITE AS REQUIRE | Feb 2, 2023 | IN VIOLATION | — |
| 1222377 | Aug 30, 2018 | FAILURE TO COMPLY WITH THE COMMISSIONRS ORDER CONTAINED IN SUMMONS/VI | Dec 20, 2018 | ADMIT/IN-VIO | — |
| 1399216 | May 18, 2018 | FAILURE TO SUBMIT ACCEPTABLE 8TH ROUND REPORT OF CRITICAL EXAMINATION | Apr 4, 2019 | IN VIOLATION | — |
| 1378533 | Mar 12, 2018 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATIO | Jun 14, 2018 | IN VIOLATION | — |
| 1265353 | Mar 12, 2018 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATIO | Jun 14, 2018 | IN VIOLATION | — |
| 1265364 | Mar 12, 2018 | FAILURE TO COMPLY W/COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VIOLATIO | Jun 14, 2018 | IN VIOLATION | — |
| 1396613 | Nov 14, 2017 | FAILURE TO MAINTAIN EXTERIOR BUILDING.39 FLOOR NORTH ROOF-WATER TANK D | Jan 4, 2018 | STIPULATION/IN-VIO | — |
| 1326528 | Jun 20, 2017 | 59U15;68B7;69M7:NO TAG STATING DATE OF ANNUAL BRAKE MAINTENANCE ON CON | Aug 10, 2017 | STIPULATION/IN-VIO | — |
| 97355 | Jun 20, 2017 | 68B7;59U15;69M7;80M7:NO LOG ENTRY OF DATE OF ANNUAL BRAKE MAINTERNANCE | Aug 10, 2017 | STIPULATION/IN-VIO | — |
| 97369 | Jun 20, 2017 | 59U15;68B7:NO TAG STATING DATE OF ANNUAL BRAKE MAINTENANCE,NO ENTRY OF | Aug 10, 2017 | STIPULATION/IN-VIO | — |
| 1580755 | May 31, 2017 | 100## FAILURE TO REPORT AN ELEVATOR ACCIDENT. FAILURE TO REPORT AN | Dec 7, 2017 | IN VIOLATION | — |
| 1580994 | May 31, 2017 | CU-16I10,99M05. 16I-CEASE USE-DUE TO FAULTY DOOR(LOWER LEVEL) CALL | Dec 7, 2017 | IN VIOLATION | — |
| 1043422 | Jan 20, 2010 | 12X7.12X CAR LIGHTING PROVIDE RATED BULBS FOR CAR LIGHTS AND REPAIR FI | Mar 11, 2010 | IN VIOLATION | — |
| 1043404 | Sep 18, 2009 | 62I11.12I10.03I10.62 REPLACE 2 CWT SHACKLES DAMAGED DURING TESTING 1 2 | Nov 12, 2009 | DEFAULT | — |
| 612032 | Mar 18, 2009 | 98U05 | May 7, 2009 | DEFAULT | — |
| 1043390 | Aug 15, 2008 | 34I11.34I11 REPLACE SADDLE ON 23 FL | Oct 9, 2008 | DEFAULT | — |
| 1124122 | Apr 25, 2008 | 05I1010H1131H1139O0238O0266Y1384M0712Q0784L1014M0739Q07. 05I10 REPAIR | Jun 12, 2008 | WRITTEN OFF | — |
| 177804 | Jul 7, 1997 | 22D,30P,57Y,57# 30-NO ACCESS TO CAR TOP 57-OIL PIT FLOR 57- PIT AS A S | Oct 30, 1997 | IN VIOLATION | — |
| 101512 | Jun 9, 1993 | WORK WITHOUT A PERMIT WORK NOTED DEMOLITION OF 1 STORY BUILDING WITH- | Nov 18, 1993 | IN VIOLATION | — |
| 21006 | Aug 21, 1990 | FAILURE TO REMOVE COMBUSTIBLE MATERIAL AT REASONABLE INTERVALS-ON ALBA | Nov 15, 1990 | IN VIOLATION | — |
| 89375 | Jul 16, 1990 | FAILURE TO HAVE SITE SAFETY MANAGER PRESENT AS REQUIRED. | Sep 13, 1990 | IN VIOLATION | — |
| 22430 | Feb 21, 1990 | UNSAFE STORGAE OF MATERIAL AT THE EDGE OF THE BLDG. REMEDY: REMOVE | Sep 6, 1990 | DEFAULT | — |
| 26770 | Feb 21, 1990 | UNSAFE STORAGE OF MATERIAL AT EDGE OF BLDG. REMEDY: REMOVE. | Apr 6, 1990 | IN VIOLATION | — |
| 25414 | Dec 19, 1989 | FAILURE TO PROVIDE ESCAPE HATCH. POURING THE 38 FLOOR OPEN FLAMES | Feb 2, 1990 | IN VIOLATION | — |
| 25241 | Oct 17, 1989 | PERSONNEL RIDING ON MATERIAL HOIST DEFECT IS ONE MAN RIDING THE MATERI | Dec 1, 1989 | IN VIOLATION | — |
| 25270 | Oct 11, 1989 | FAILURE TO DO ADEQUATE HOUSEKEEPING DEBRIS IS THROWN ALL OVER THE 14,1 | Dec 1, 1989 | IN VIOLATION | — |
| 16358 | Sep 13, 1989 | FAILURE TO DO ADEQUATE HOUSEKEEPING IN 3,4 7 5 FLPILES OF CONCRETE DEB | Nov 30, 1989 | IN VIOLATION | — |
| 16026 | Sep 13, 1989 | RESHORES NOT BANDED AS REQUIRED BY LL61/87 ART 3/1/6 IN THE FOLLOWING | Nov 30, 1989 | IN VIOLATION | — |
| 24790 | Sep 6, 1989 | HORIZONTAL SAFETY NETTING NOT PROVIDED FARNING 9FL 8 FL POURED CONCRET | Oct 20, 1989 | IN VIOLATION | — |
| 1149286 | Mar 29, 1989 | FAILURE TO HAVE SITE SAFETY MANAGER PRESENT AS REQUIRED DURING ON GOIN | Jun 1, 1989 | WRITTEN OFF | — |
| 103758 | Aug 12, 1988 | WORK WITHOUT A PERMIT WORK NTOED ENTIRE BUILDING DEMOLISHED NO PERMIT | Dec 29, 1988 | DEFAULT | — |