OpenViolations
/

20 Broad Street

ManhattanBIN 1000816
1 open Class C$1,875.00 recorded as dueHPD registration valid
Export CSV
OverviewHealth scoreTimelineFinesOwner
Open Class C
1
Immediately hazardous
Open Class B
0
Hazardous
Open Class A
0
Non-hazardous
Fines due
$1,875.00
Balance on OATH/ECB summonses
Permits on file
67
DOB permit records
Last activity
Mar 19, 2026
DOB record

Building health score

A composite of public indicators. Every input is a public record. See the full methodology.

A
Health score · Jul 29, 2026
Scored from the 300 most recent of 366 public records for this building
Open Class C violations
Immediately hazardous, uncertified
This building 1
Open Class B violations
Hazardous
This building 0
Heat & hot water records
Violations and complaints, last 24 months
This building 0
Unpaid penalties
OATH/ECB summonses with balance due
This building $1,875
Bedbug filings with infestations
Annual LL69 filings on record
This building 0
Tenant litigation
Open HP actions in Housing Court
This building 0
Active vacate order
HPD or FDNY order to vacate, still in effect
This building No

Unified timeline

Records from every agency, interleaved. Showing the 300 most recent of 366 records on file; the CSV below has the full history.

Download this timeline (CSV) →
Mar 19, 2026
Mar 19, 2026
Jan 8, 2026
Jan 8, 2026
Jan 5, 2026
Aug 4, 2025
Feb 26, 2025
Feb 26, 2025
Feb 26, 2025
Dec 2, 2024
Oct 21, 2024
Oct 21, 2024
Oct 21, 2024
Oct 21, 2024
Jul 31, 2024
Jul 31, 2024
Apr 15, 2024
Apr 15, 2024
Apr 15, 2024
Apr 15, 2024
Apr 15, 2024
Apr 15, 2024
Jan 15, 2024
Jul 19, 2023
Jul 19, 2023
Jul 13, 2023
Jun 20, 2023
Jun 20, 2023
Jun 20, 2023
Jun 20, 2023

OATH / ECB summonses & fines

$1,875.00 is recorded as due across the 24 summonses below, out of $52,137.00 in penalties imposed. The city’s published records do not show whether a penalty was paid, reduced, or written off.

OATH and ECB summonses for 20 Broad Street
1816544Jan 8, 2026ENTIRE DEVICE INOPERATIVE NOTIFY D.O.B FOR INSPECTIONOct 15, 2026PENDING$1,250.00
1668206Apr 14, 202352/0/2 HOIST ROPES DIRTY CLEAN,99/BB/7 HOIST ROPES EXPIRED TAG PROVIDEJun 22, 2023DEFAULT
1276680Oct 12, 20183314.4.4.4 STABLE AND SECURE (SUPPORTED SCAFFOLD) AT TIME OF MY INSPECDec 6, 2018IN VIOLATION
1441587Aug 28, 2018FAILED TO PROVIDE DOCUMENTS.AT TIME OF INSPECTION I REQUESTED TO SEE LOct 18, 2018IN VIOLATION$625.00
1268357Jun 20, 2018GUARD RAILS/AT TIME OF INSPECTION FOR 30 STRY ALTERATION I OBSERVED ONOct 4, 2018IN VIOLATION
1268356Jun 20, 2018BC3301.7.DESIGN DRAWING.AT TIME OF INSPECTION FOR A 30 STORY BUILDING Oct 4, 2018IN VIOLATION
1268368Jun 20, 2018HOUSEKEEPING.AT TIME OF INSPECTION FOR A 30 STORY ALTERATION AT APPROXOct 4, 2018IN VIOLATION
1299376Mar 15, 20183301.2 HOLES NOT COVERED. AT TIME OF INSPECTION OF ALT 1 ON 30 STORY BMay 3, 2018IN VIOLATION
1314411Jan 31, 2018INSURANCE-DISABILITY EXPIRED. IN RESPONSE TO A INCIDENT WHERE A WORKERAug 2, 2018IN VIOLATION
1314409Jan 31, 2018SEC. 3310.10.1 ORIENTATION(FAILURE TO PROVIDE SITE SAFETY ORIENTATION Jul 26, 2018IN VIOLATION
1314407Jan 31, 2018FAILURE TO NOTIFY DOB OF AN ACCIDENT. IN RESPONSE TO A INCIDENT OF A AJul 26, 2018IN VIOLATION
1298413Jul 14, 2017FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONSTRUCTIONJul 12, 2018IN VIOLATION
1298538Jul 11, 2017FAILURE TO SAFEGUARD ALL PERSONS AFFECTED BY CONSTRUCTION OPS. REPORTIApr 19, 2018IN VIOLATION
1178826May 17, 2017BC3301.1.3 MANUFACTURER SPECIFICATIONS:MILLER GRIP FALL ARREST SYSTEM.Sep 7, 2017IN VIOLATION
1663905Apr 7, 2017FAILURE TO COMPLY WITH THE COMMISSIONER'S ORDER CONTAINED IN SUMMONS/VNov 16, 2017IN VIOLATION
1012365Mar 29, 20171L10,16R10. 1I10-IN CAR STOP SWITCH DOES NOT WORK; 16R10-CLOSE ALL Sep 7, 2017IN VIOLATION
1012363Mar 29, 20173L10 CAB FLOOR IS ROTTEN ALL THE WAY THROUGH TO THE METAL FLOORING.NESep 7, 2017IN VIOLATION
803027Mar 23, 2017WORK WITHOUT A PERMIT.NOTE:AT TIME OF INSPECTION OF A 30 STORY ALTERATMay 11, 2017IN VIOLATION
803048Mar 23, 2017FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CMay 11, 2017IN VIOLATION
803037Mar 23, 2017PRESENCE AT SITE.NOTE:AT TIME OF INSPECTION OF A 30 STORY ALTERATION,CMay 11, 2017IN VIOLATION
1166769Dec 19, 2016FAILURE TO PROVIDE ADEQUATE SAFETY MEASURES SUCH AS SIDEWALK SHED,NETTFeb 2, 2017IN VIOLATION
1143875Dec 18, 2016FAILURE TO MAINTAIN EXTERIOR BLDG WALL. NOTED: AT EAST ELEVATION(EXP#1Feb 2, 2017IN VIOLATION
934527Jan 10, 2014SEC. AREAS TO BE PROTECTED. NOTED: AT TIME OF INSPECTION C-HOOKS IN COMar 20, 2014IN VIOLATION
751151Feb 5, 2009WORK W/O PERMIT. WORK NOTED: AT 27 FL OF PREMISES DEMOLISHED 80% OF FUMar 26, 2009IN VIOLATION